Subject to change without notice
Owner Manual
Operating Instructions
2.1A-30004-A02
Page 20 of 36
LINCOLN GmbH & Co. KG Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Programming mode
* To access the programming mode, press both keys at
the same time > 4 seconds.
Programming options - Pause time:
P1 0 - 59 hours
P2 0 - 59 minutes
Min. pause time 4 minutes
Max. pause time 59 hours 59 minutes
Set hours P1
* Settings are made in one direction: 0, 1, 2, 3, ... 59 h
Key pressed once........................increases by 1 hour
Key pressed continuously...................quick sequence
The fields hour and minutes are indicated by a
decimal point on the right hand for hours and on the
left hand for minutes.
Set minutes P2 (shift key)
* Settings are made in one direction: 0, 1, 2, 3, ...59 min
Key pressed once......................increases by 1 minute
Key pressed continuously....................quick sequence
Note: The minimum pause time begins with 4 minutes.
When pause times < 4 minutes (no indication of hour) the
display automatically indicates . 04. Precondition: The
programming sequence must have been carried out
completely.
Complete programming mode
* Press key. P - indicates the programming end.
Important: In order to avoid a wrong programming, make
sure to always carry out the programming sequence
completely, i.e. setting of P1 (hours), P2 (minutes) and P-
(programming end).
Complete the programming by pressing this key
(additional lubrication).
Note: If the displayed key additional lubrication is not
pressed within 30 seconds, the programming mode
remains in the previously set time.
Important: After completion of the programming sequence,
also check the setting of the pause time in the operating
mode (see page 13).
Display Press Press
Fig. 36 - Membrane key pad in programming mode
³ 4 sec
4215a99
4222a99
4214a99
4222a99
4214a99
4222a99
4214a99
4222a99
4279a00
4221a99
4220a99
4217a99
4216a99
(set key)