Quickdata Quikstop-15 Especificaciones

Busca en linea o descarga Especificaciones para Cajas De Interruptores En Serie Quickdata Quikstop-15. Quickdata Quikstop-15 Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 59
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
I
Mopra QRH
The Mopra Quick Reference Handbook
Available online at
http://www.narrabri.atnf.csiro.au/mopra/
Current Date / Version
Author
15 MAY 2013
Dr Balthasar Indermuehle (balt.indermuehle@csiro.au)
Vista de pagina 0
1 2 3 4 5 6 ... 58 59

Indice de contenidos

Pagina 1 - Mopra QRH

I Mopra QRH The Mopra Quick Reference Handbook Available online at http://www.narrabri.atnf.csiro.au/mopra/ Current Date / Vers

Pagina 2

Page 5 of 54 3. Observatory Characteristics 3.1. Location Mopra is located in the foothills of Siding Spring, near Coonabarabran in r

Pagina 3 - Table of contents

Page 6 of 54 7mm @ 42 GHz 82” ~ 80K 3mm @ 90 GHz 38” ~200K 3mm @ 115 GHz 30” ~ 600K Table 5 Beam widths and average Tsys's Frequency Efficien

Pagina 4

Page 7 of 54 Figure 2 Antenna efficiency at 12mm and 7mm

Pagina 5

Page 8 of 54 Figure 3 Tsys at 3mm from Ladd et al. The following fit is used to calculate in TOAD whether the Tsys is in range € Tsy

Pagina 6 - 1. Preamble

Page 9 of 54 Internally, MOPS contains 4 IF’s, or Bands. Refer to Figure 4 MOPS bands and IF's to see how they are arranged and relate

Pagina 7 - 1.2. Important note

Page 10 of 54 Figure 4 MOPS bands and IF's In Zoom mode, the zoom windows are arranged as depicted in the following graph. Use

Pagina 8 - 2. Changes

Page 11 of 54 Figure 5 MOPS zoom window definitions Further to this, the MOPS zoom window setups and spectral resolutions can be seen in the foll

Pagina 9 - Page 4 of 54

Page 12 of 54 Figure 6 MOPS zoom mode specifications 3.4. Data rates You need to make sure you bring enough disk spa

Pagina 10 - 3.2. System Characteristics

Page 13 of 54 4. Command references 4.1. SPD Command Action select 1 2 3 4 View both pols in IF’s 1 & 2 in separate graphs, amplitude vs. fre

Pagina 11 - Page 6 of 54

Page 14 of 54 4.2. MOTP Command Action sel * Selects all powers, required when MOPS has been restarted. sca y1 y2 Changes the Y scale of

Pagina 12 - Page 7 of 54

II THIS PAGE INTENTIONALLY LEFT BLANK

Pagina 13 - 3.3. MOPS configurations

Page 15 of 54 5. Normal procedures 5.1. Observing Checklist Before starting your observations make sure you have • Selected a good pointing sour

Pagina 14 - Page 9 of 54

Page 16 of 54 5.3. Find your zooms with mops_vis or OTF v6 or PSW v5 mops_vis is a script application written by Erik Muller, which runs on any p

Pagina 15 - Page 10 of 54

Page 17 of 54 Alternatively, you can use the graphical editor from the on the fly (OTF) or the position switch (PSW) schedule maker

Pagina 16 - Page 11 of 54

Page 18 of 54 5.5. Setting up the observatory software While observing from an ATNF supported Mopra control desk, you will be presented

Pagina 17 - 3.5. Fast mapping mode

Page 19 of 54 Screen 1 (TCS) Screen 2 (MOPS) Screen 3 (SPD) Screen 4 (TOAD) atdaemon TCS dclocks MOPS MOTP atdrivemon SPD Pointings attest

Pagina 18 - 4. Command references

Page 20 of 54 Compare the layout of the screen you have just created, try to make it look similar: Figure 9 VNC screen 1 Then set

Pagina 19 - 4.3. MOPS

Page 21 of 54 o When the window has come up, dismiss the skyviewer window (unless you would like to use it), and dismiss any wa

Pagina 20 - 5. Normal procedures

Page 22 of 54 Figure 11 VNC screen 3 • Clicke the up arrow in the virtual screen square until it says “Pointing”. • Right click on the back

Pagina 21 - Page 16 of 54

Page 23 of 54 Figure 12 VNC screen 3 on the pointing virtual desktop • Lastly, click on the up arrow one more time to access the “Utilities” scr

Pagina 22 - Page 17 of 54

Page 24 of 54 purpose make use of the virtual screen button’s top right and bottom left arrows to click into to the next available virtual desktop:

Pagina 23 - Page 18 of 54

III Table of contents 1.! Preamble... 1!1.1.! How to use the Quick Reference Handbook (Q

Pagina 24 - Page 19 of 54

Page 25 of 54 Figure 14 VNC screens and virtual desktop arrangements in multi screen mode 5.6.2. Two screen setup In the two screen setup: • On

Pagina 25 - Figure 9 VNC screen 1

Page 26 of 54 section (5.7.1) detailing one facility we have installed to facilitate this coordination. This is to • Exchange informati

Pagina 26 - Figure 10 VNC screen 2

Page 27 of 54 If you’re in two-screen mode and would like to make sure MOPS is not running already, in the terminal window that starts MOPS

Pagina 27 - Figure 11 VNC screen 3

Page 28 of 54 Wavelength Subreflector focus position 3mm 16.2 7mm 16.2 12mm 16.2 2.5cm 10.0 3cm -2.0 20cm -25 Table 12 Focus positions Select the

Pagina 28 - Page 23 of 54

Page 29 of 54 5.8.4. Starting your observations Upon completion of the pointing, you can start your schedule by loading the schedule

Pagina 29 - 5.6.1. Four screen setup

Page 30 of 54 Figure 17 QuickData interface 5.8.6. Processing your data Your data is initially stored on MPCCC1 (the MOPS control computer), and

Pagina 30 - 5.6.2. Two screen setup

Page 31 of 54 Mopra data is stored in /DATA/ARCHIVE_1/Mopra/ accessible from Kaputar. The file name convention is YYYY-MM-DD_HHMM-MXXX.rpf,

Pagina 31 - Page 26 of 54

Page 32 of 54 Figure 18 Beam position map on a windy day Compare this to a map with missing scans. If you see a map like this, you are ve

Pagina 32 - 5.8.2. Setting focus

Page 33 of 54 Figure 19 Beam position map with scans gone badly 5.10. Monitoring 5.10.1. TOAD TOAD (Telescope Operator Alerting Display) is a w

Pagina 33 - 5.8.3. Pointing

Page 34 of 54 Use this URL from inside or outside ATNF to load TOAD: http://mopra-ops.atnf.csiro.au/TOAD TOAD is compatible with Mozilla based b

Pagina 34 - Page 29 of 54

IV 5.8.2.! Setting focus... 27!5.8.3.! Pointing ...

Pagina 35 - 5.8.6. Processing your data

Page 35 of 54 The SYNOPtic page displays (Refer to Figure 21 TOAD synoptic display): • Antenna state (TRACKING, SLEWING, STOWED etc.) • Wea

Pagina 36 - Page 31 of 54

Page 36 of 54 • Static quick access data. This data is always displayed, regardless of which page is selected. o Drive state, Azimuth a

Pagina 37 - Page 32 of 54

Page 37 of 54 Always follow the instructions TOAD gives to recover from a failure. Acquaint yourself with the CLEAR and RECALL functions

Pagina 38 - 5.10. Monitoring

Page 38 of 54 Figure 22 Wind monitoring page in Monica

Pagina 39 - Page 34 of 54

Page 39 of 54 5.11. Finishing the observations When your observations are done, either hand over the telescope to the next observers

Pagina 40 - Page 35 of 54

Page 40 of 54 6. Abnormal procedures Most system malfunctions and advisory conditions are programmed into TOAD. You will be presented with

Pagina 41 - Page 36 of 54

Page 41 of 54 • After MOPS has restarted, TCS must be reconnected to MOPS. For that purpose, o dismiss the warning messages informing you

Pagina 42 - 5.10.2. Monica

Page 42 of 54 6.4.2. Via MAPS reset button • Walk to the MAPS panel in the PMON rack at Narrabri (this obviously only works if you’re on site in

Pagina 43 - Page 38 of 54

Page 43 of 54 6.6. Problems with the VNC sessions 6.6.1. VNC Server does no longer accept keyboard input Right-click with the mouse on the

Pagina 44 - Page 39 of 54

Page 44 of 54 6.8. Unable to bring GTP’s down/up into normal range Under some circumstances (usually weather inflicted), it is possible that you a

Pagina 45 - 6. Abnormal procedures

V 9.2.1.! 30min WindMax High ... 47!9.2.2.! Telescope idle and not stowed...

Pagina 46 - 6.4. Restarting the ACC

Page 45 of 54 7. Emergency If an emergency occurs that is not covered by any of the other checklists or is not covered by TOAD: • Contact the Du

Pagina 47 - Page 42 of 54

Page 46 of 54 8. Glossary Moprabub Your nemesis. Do you know what "nemesis" means? A righteous infliction of retribution man

Pagina 48 - 6.7. Generator messages

Page 47 of 54 9.2.1. 30min WindMax High Message ID: 3 Triggers when: The 30 minute maximum wind is greater or equal 35km/h and the ant

Pagina 49 - Page 44 of 54

Page 48 of 54 Triggers when: the ACC is in local mode. The ACC can be put into local or remote mode by connecting to the remote con

Pagina 50 - 7. Emergency

Page 49 of 54 The lightning threa level is derived from the lightning detector and expresses a threat level indicating the need to run

Pagina 51 - 9. TOAD Message Reference

Page 50 of 54 This error can have many different origins and does not necessarily mean something is broken. When a hardware stow

Pagina 52 - Page 47 of 54

Page 51 of 54 9.3.15. WIND Hardware Stow Message ID: 31 Triggers when: Mopra anemometers have issued a hardware stow. This stow cannot be overr

Pagina 53 - 9.3. Error Messages (Red)

Page 52 of 54 9.3.22. MOPS Pol A noise diode faulty Message ID: 40 Triggers when: Pol A SDO is below 0.002 or above 1 This is indicative of the

Pagina 54 - Page 49 of 54

Page 53 of 54 Figure 5 MOPS zoom window definitions ... 11!Figure 6 MOPS zoom mode specific

Pagina 55 - Page 50 of 54

Page 54 of 54 THIS PAGE INTENTIONALLY LEFT BLANK

Pagina 56 - Page 51 of 54

Page 1 of 54 1. Preamble 1.1. How to use the Quick Reference Handbook (QRH) The QRH is meant to be used as a reference for all observ

Pagina 57 - 10. Index of Figures

Page 2 of 54 Normal procedures provide you with checklists on how to set up the software when you take over from previous observers, and ho

Pagina 58 - 11. Index of Tables

Page 3 of 54 2. Changes Date Who What 20 JUN 2009 ind006 QRH created 06 JUL 2009 ind006 New chapters: 5.2 Creating your schedule 5.3 Selecting yo

Pagina 59 - Page 54 of 54

Page 4 of 54 5.7.1 Using Python Chat for coordination Error! Reference source not found. Error! Reference source not found. Modified: Repla

Comentarios a estos manuales

Sin comentarios